Foundry & industrial processing Machinery EQUIPMENT & SYSTEMS

U.S. & Canada Call 1.800.457.5456

HCCL-Series Heater / Cooler / Classifier

General

The process of controlled heating, cooling, and classification of sand passing through this unit is achieved by the balanced use of air from a supplied blower and heated or cooled water in the form of a heat exchanger bundled designed integrally in the unit. This ensures that the sand being discharged from the unit is not only at the temperature best suited to the customer’s operation, but is also free of dust and matches the desired grain distribution of the sand.

  • Tonnage and thermal transmission rates are based on silica sand (50-75 AFS).
  • Heating Parameters: 45 degrees Fahrenheit Incoming to 85 degrees Fahrenheit Discharge (Controlled) - Heating Energy Source - Natural Gas Hot Water Boiler
  • Cooling Parameters: 105 degrees Fahrenheit Incoming to 85 degrees Fahrenheit Discharge (Controlled) - Cooling Energy Source - City Water at 65 degrees Fahrenheit

  • HCCL-Series

Options

  • Cooling Tower
  • Chiller Package
  • Electric Boiler
  • Extended Length
  • Custom sizing for specialty sands and installations

HCCL-Series Full Specifications

GuidePalmer HCC Design: In-Depth Guide

HCCL-Series Heater Models

Model

HCCL-3

HCCL-6

HCCL-10

HCCL-20

HCCL-30

HCCL-45

HCCL-60

Nominal System Tons Per Hour Based on General Specifications Above
3
6
10
20
30
45
60
Blower Motor
3 HP TEFC
3 HP TEFC
3 HP TEFC
5 HP TEFC
10 HP TEFC
15 HP TEFC
20 HP TEFC
Inlet Butterfly Valve Size
4"
4"
4"
6"
6"
8"
8"
Heating BTU's
58,300
100,000
166,000
333,000
500,000
750,000
1,000,000
Cooling BTU's
29,200
50,000
83,000
166,000
250,000
375,000
500,000
Maximum Pump GPM (Cooling Water)
15
25
45
70
105
160
190
Exhaust Requirements
300 SCFM
350 SCFM
500 SCFM
900 SCFM
1200 SCFM
1500 SCFM
2000 SCFM

HCCL-Series Gallery

Additional Palmer Products

Improve your productivity with from Palmer.

Contact Us to learn more!

Call us at 1.800.457.5456 or fill out our simple form.